PENGARUH PENAMBAHAN COOLING TOWER TERHADAP PENURUNAN SUHU AIR BAK PENAMPUNG PADA PROSES DESTILASI UAP DAUN SEREH DAPUR (CymbopogonCitratus)

Delfinsianus Ome, Zuhdi Ma'sum

Abstract


Heat exchange causes cold water to change temperature where the cooling water temperature to rise because the resulting heat is carried by a fluid which is absorbed by the water. To overcome that we need some cooling to reduce the temperature of the water is by using a cooling tower. The goal is to find out and determine "the effect of adding a cooling tower to decrease the water temperature in the cooling bath steam distillation process of (Cymbopogon citratus) leaves ". Measure the temperature every 30 minutes after the distillate water dripping, and the process of repeated measurements simultaneously on a water bath cooler, condenser, cooling tower (cooling tower) and the distillate water. The process of measuring the temperature using a cooling tower with a water tank initial temperature was 270C with the old process for 3 hours. From this research can be concluded that: 1)At the time of the process without using an intermediary Cooling Tower For media water cooler during the 3 hour difference between 2-30C temperature rise to a maximum temperature ranging between 41-430C. 2) Cooling Tower Process using water as a cooling medium for 3 hours process, the maximum temperature ranges between 31-340C and the difference in temperature rise between 1-20C. 3)Comparison of the temperature of the process without the use of Cooling Tower and Cooling Tower using cooling water as its medium very different temperature difference is 34 : 430C with a temperature difference of 90C without using the Cooling Tower to use the Cooling Tower.

Keywords: Cooling Tower, temperature, distillation, Cymbopogon citratus

Full Text:

PDF

References


A. Halili, B. Teguh P., Sarwono, Laporan Pengujian Karakteristik Prestasi Kerja Menara Pendingin Basah, No: 94.14.01.1, 7 Nopember 1994, LTMPBPPT,Serpong.

Bambang Teguh P.(2006).Simulasi Numerik Aliran Udara di Dalam Cooling Tower, Jurnal Sainstech, 16 (3), ISSN 1410 – 7104, Madinah.

HeriyaniImut.http://wordpress.com/ 2013/03/29/perbaikan-final pendahuluan-cooling-tower-praktikum-otk-1/2015.

J. R. Singham,(1983). Heat Exchanger DesignHandbook, Hemisphere Publishing Corporation, New York, USA.

Roepandi, Opan.(2008). Pengoperasian Sistem Air Pendingin. Surabaya:PT.IndonesiaPower.

UNEP.(2006).MesinPendingin.[Online].Tersedia:http://www.lunibuk.com/home.php?action=list&dir=PUSTAKA/TEKNIK.DAN.SAINS&order=name&srt=yes&nama=PUSTAKA/TEKNIK.DAN.SAINS/menara.pendingin.pdf.swf&cekd=ok&link=&namafile=menara.pendingin.p df. [3 Maret 2013].

UNEP.(2006).Fan dan Blower.[Online]. Tersedia:www.energyefficiencyasia.org. [3 Maret 2012]


Refbacks

  • There are currently no refbacks.


Copyright (c) 2018 eUREKA



eUREKA : Jurnal Penelitian Teknik Sipil dan Teknik Kimia

ISSN 2548-771X (online)

Email : [email protected]

 

Editorial Office :
Fakultas Teknik, Universitas Tribhuwana Tunggadewi Malang

Jl. Telaga Warna Blok C, Tlogomas, MALANG 65144, Jawa Timur
Tel / fax : (0341) 565 500 / (0341) 565 522

 

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License

 

View My Stats